Troubles shooting

Verify that is using the right power cord/adapter (DC 12-48V), please don’t use the power

adapter with DC output bigger than 48V, or it will burn this converter down.

Select the proper UTP cable to construct user network. Please check that is using the right

cable. use unshielded twisted-pair (UTP) or shield twisted-pair ( STP ) cable for RJ-45

connections: 100 Category 3, 4 or 5 cable for 10Mbps connections or 100 Category 5 cable

for 100Mbps connections. Also be sure that the length of any twisted-pair connection does not

exceed 100 meters (328 feet).

Diagnosing LED Indicators: the Switch can be easily monitored through panel indicators to

assist in identifying problems, which describes common problems user may encounter and

where user can find possible solutions.

If the power indicator does turn on when the power cord is plugged in, user may have a problem

with power cord. Than check for loose power connections, power losses or surges at power

outlet. If user still cannot resolve the problem, contact user local dealer for assistance.

If the Industrial switch LED indicators are normal and the connected cables are correct but the

packets still cannot transmit. Please check user system’s Ethernet devices’ configuration or

status.