8

Cabling

Using four twisted-pair, Category 5 cabling for RJ-45 port connection. The cable between the

converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328

ft.) long.

Fiber segment using

single-mode connector type must use

9/125 um single-mode fiber cable.

User can connect two devices in the distance up to

30 Kilometers.

Fiber segment using

multi-mode connector type must use 50 or 62.5/125 um multi-mode fiber

cable. User can connect two devices up to

2Km distances.

Wiring the Power Inputs

Please follow below steps to insert the power wire.

[NOTE] The wire range of terminal block is from 12~ 24 AWG.

ATTENTION

This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam.

V- V+

V- V+

1. Insert the positive and negative wires into the V+ and V- connector on the

terminal block connector.

2. To tighten the wire-clamp screws for preventing the DC wires to loose.