background image

44

Save Configuration

Save the industrial switch

configuration to the flash memory. Power off the industrial switch without

the saving, all changed configuration will lost.

Click the

Save Flash

button the save the configuration

Save Configuration Interface

Rate Control

Set up every port’s bandwidth rate and packet limitation type

Limit Packet type: Select the packet type that wants to filter. The packet types have all

type packet, broadcast/multicast/unknown unicast packet, broadcast/multicast packet, and

broadcast

packet

only.

The

broadcast/multicast/unknown

unicast

packet,

broadcast/multicast packet, and broadcast packet only are only for ingress packet. The

egress rate only supports all type packets

Band Width: The port1 ~ port 8, supports port ingress and egress rate control. For

example, assume port 1 is 10Mbps, users can set it’s effective egress rate as 1Mbps,

ingress rate is 500Kbps. The switch performs the ingress rate by packet counter to meet

the specified rate

Ingress: Select the port effective ingress rate. The valid range options are 128kbps,

256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB. The default value is “disable”

Egress for all: Select the port effective egress rate. The valid range options are 128kbps,

256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB. The default value is “disable”

And then, click

Apply

button to apply the configuration