RS-232/RS-422/RS-485 Serial Data Port

The connections for these standard interfaces are made through the DB25S
connector on the rear panel. For all RS-232 input and output signals, the
XiII printer follows both the Electronics Industries Association’s (EIA)
RS-232 specifications and the Consultative Committee for International
Telegraph and Telephone (CCITT) V.24 standard signal level specifica-
tions.

Table 10 shows the pin configuration and function of rear panel serial data
connector on the XiII-Series printers.

Table 10. RS-232/RS-422/RS-485 Pinouts

Pin No.

Description

1

Frame ground for cable shield

2

TXD (RS-232 transmit data) output from printer

3

RXD (RS-232 receive data) input to printer

4

RTS (RS-232 request to send) output from printer

6

DSR (data set ready)input to printer

7

Signal ground for RS-232

9

+5 VDC source output (1 Amp maximum)

11

Signal ground reference for RS-422/RS-485

13

RS-422/RS-485 data input A (-)

14

RS-422/RS-485 data output A (-)

16

RS-422/RS-485 data input B (+)

19

RS-422/RS-485 data output B (+)

20

DTR (RS-232 data terminal ready) output from printer

NOTE: Pins 5, 8, 10, 12, 15, 17-18, 21-25 are not used and are unterminated.