Media and Ribbon Sensor Calibration
NOTE: Before you begin this procedure, make sure that the Maximum Length is set to a

value equal to or greater than the length of the labels you are using. If the Maximum

Length is set to a lower value, the calibration process will assume that continuous media is

in the printer. See page 34 for more information.
There are two different types of calibration that can be performed by the printer:
1) Standard Calibration. Pressing the Calibrate key on the printer’s front panel causes the

printer to feed media and ribbon and set the values it detects for media, media backing

material (the spaces between labels), media out, and ribbon or no ribbon (which

determines the print mode—Thermal Transfer or Thermal Direct). This type of calibration

also occurs as part of the “Sensor Profile” and “Media and Ribbon Calibrate” procedures

specified below.
2) Media and Ribbon Sensor Sensitivity Calibration. Performing the “Media and Ribbon

Calibrate” procedure below first resets the sensitivity of the sensors to better detect the

media and ribbon you are using. With the sensors at their new sensitivity, the printer then

performs the standard calibration described above. Changing the type of ribbon and/or

media may require resetting the sensitivity of the Media and Ribbon Sensors. Indications

that the sensitivity may need to be reset would be a “Check Ribbon” light on with the

ribbon properly installed or non-continuous media being treated as continuous media.

Press

Display Shows

Action/Explanation

SENSOR

PROFILE

Sensor Profile Press Next/Save to skip this standard

calibration procedure and continue with “Media and Ribbon

Calibrate” parameter which follows.
Press the right oval key to initiate this standard calibration

procedure and print a Media Sensor Profile.
See Figure 10, “Media and Ribbon Sensor Profile Sample

Printout,” on page 46.
The Media Sensor Profile may be used to troubleshoot

registration problems that may be caused when the Media

Sensor detects preprinted areas on the media or experiences

difficulty in determining web location. If the sensitivity of the

Media and/or Ribbon Sensors MUST be adjusted, use the

Media and Ribbon Sensor Sensitivity procedure below.

MEDIA AND

RIBBON

CALIBRATE

Media and Ribbon Sensor Sensitivity Press Next/Save to skip

the calibration procedure shown on the next page and

continue with “Setting Host Port” parameter which follows.
Press the right oval key to start the calibration procedure.
This procedure is used to adjust the sensitivity of the Media

and Ribbon Sensors.
NOTE: The procedure must be followed exactly as presented

on the next page. All steps must be performed even if only

one of the sensors requires adjustment.