Media and Ribbon Calibration Procedure

Press

Display Shows

Action/Explanation

LOAD BACKING

Press the left oval key to cancel the operation, or do the

following:
Open the Printhead. Remove as many labels as needed to

load a section of blank backing material under the media

sensor (just behind the printhead). See Figure 4, “Upper Media

Sensor Adjustment,” on page 16 to locate the sensor.

REMOVE

RIBBON

Press the left oval key to cancel the operation or do the

following:
1) Remove the ribbon (sliding it as far to the right as possible

will have the same effect as removing it.)
2) Close the Printhead.

CALIBRATING

PLEASE WAIT

The printer automatically adjusts the scale (gain) of the signals

it receives from the media and ribbon sensors based on the

specific media and ribbon combination you are using. On the

sensor profile, this essentially corresponds to moving the

graph up or down to optimize the readings for your

application.

----

RELOAD ALL

When “RELOAD ALL” is displayed:
1) Open the Printhead and pull the media forward until a label

is positioned under the Media Sensor.
2) Move the ribbon back to its proper position.
3) Close the Printhead.

MEDIA AND

RIBBON

CALIBRATE

Now that the scale has changed, the printer performs a

calibration equivalent to pressing the Calibrate key. During this

process, the printer checks the readings for the media and

ribbon based on the new scale you’ve established, determines

the label length, and determines whether you are in thermal

direct or thermal transfer print mode. The process is now

complete! To see the new readings on the new scale, print a

Sensor Profile (see previous page).

Zebra XiII-Series User’s Guide

37

49