Display Shows

Action/Explanation

HEAD TEST

COUNT

Setting the Head Test Count

Press the left oval key to

move to the next digit position, press the right oval key to

change the value of the digit.
Default: 0000 (Disables the test)

Range: 0000 to 9999

The printer periodically performs a test of the printhead

functionality, called a “Printhead Test” or “Head Test”. This

parameter establishes how many labels are printed between

these internal tests.

HEAD RESISTOR

Setting the Head Resistor Value

Press the left oval key to

move to the next digit position, press the right oval key to

increase the value of the digit.
CAUTION: This parameter should only be changed by

qualified personnel!
Initial Value: Factory-set to match the printhead shipped with

your printer (varries).
Default Value: 0500

Range: 0500 - 1175

This value has been pre-set at the factory to match the

resistance value of the printhead. It will not need to be

changed unless...
1) The printhead is replaced.
2) The printer is set to the factory defaults. (The factory default

value is usually lower than the actual resistance value.)
CAUTION: DO NOT set the value higher than that shown on the

printhead. Setting a higher value may damage the printhead!
Before replacing a printhead, look on the bottom of the

printhead element for the label that shows the resistance

value (ohm value).

VERIFIER PORT

Setting the Verifier Port

Press the right or left oval key to

display other choices.
Default: Off

Selections: Off, 1 VER-RPRNT, 2 VER-THRUPUT

The Auxiliary Port is used to determine how the printer will

react to the Zebra On-Line Verifier. There are currently three

operating conditions for this port.
• Off—The Verifier Port is off.
• 1 VER-RPRNT ERR—Label reprinted if verifier detects an

error. If a bar code is near the upper edge of the label, the

label will be fed out far enough to be verified and then backfed

to allow the next label to be printed and verified.
• 2 VER-THRUPUT—Allows greatest throughput but may not

indicate a verification error immediately upon detection. May

print from 1 to 3 labels before an error is recognized and

printing stops.
For more information on the operation of the optional verifier,

refer to the documentation provided with that option.