Zebra Technologies XiII-Series User Manual

Page 74

Advertising
background image

Symptom

Diagnosis

Action

Long tracks of missing print

on several labels.

Wrinkled ribbon.

See “Wrinkled Ribbon” in this

table.

Printhead is dirty.

Clean the printhead. See page

52.

Print element is damaged. Call a service technician.

Fine gray lines on blank labels

at angles.

Wrinkled ribbon.

See “Wrinkled Ribbon” in this

table.

Wrinkled ribbon.

Ribbon fed through

machine incorrectly.

See “Ribbon Loading”

on page 18.

Incorrect darkness setting.

Set darkness to the lowest

setting possible for good print

quality. See “Setting the

Darkness” on page 32.

Incorrect printhead

pressure or balance.

Set the pressure to the

minimum needed. See

“Adjustments” on page 56.

Media not feeding

properly; it is “walking”

from side to side.

Make sure that the media is

snug by adjusting the Media

Guides.

Strip Plate needs adjusting.

Call a service technician.

Roller under Printhead

needs realigning.
Ribbon Supply tension

needs adjusting.
Printhead Shaft needs

adjusting using the Wear

Plate.
Printhead needs realigning

with Platen Roller.
Ribbon Take-Up tension

needs adjusting to the

minimum value.
Three-point mount for

Ribbon Supply Spindle

needs adjusting. (Not

applicable to the 220XiII

printer.)
Ribbon supply core

slipping; spindle blades

need adjusting.

62

Zebra

XiII-Series User’s Guide

74

H:...Xi2UsersGuideR2.vp

Fri Aug 07 10:36:38 1998

Color profile: Disabled

Composite Default screen

Advertising