Xantrex Technology DR1524W User Manual

Page 88

Advertising
background image

Specifications

A–6

975-0012-01-02 Rev A

Auto Low Battery
Protection enabled

11 V

11 V

22 V

22 V

DC Charger Rate
(Adjustable)

0 to 70 amps

0 to 35 amps

0 to 17.5 amps

0 to 70 amps

Common Specifications:

Voltage Regulation
(maximum)

± 5%

Voltage Regulation
(Typical)

±2. 5%

Waveform

modified sine wave

Load Power Factor
(allowed)

0.5 to 1.0 (leading or lagging)

Adjustable Load
Sensing Range

5 watts minimum to 100 watts maximum

Series Operation

NO

Force Air Cooling

Variable speed fan

Automatic Transfer
Relay

20 amps

Number of Charging
Profiles

10

Three-stage Charging

Yes (float, absorption, bulk)

Temperature Comp
Probe (BTS)

optional

Remote Control (RC8)

d

optional

a.Specifications subject to change without notice.
b.This is the minimum AC current required to obtain full pass-through and maximum battery charging.
c.Product may not meet voltage regulation specifications at other than "Input Nominal" at full-rated load.
d.Also compatible with the RC4.

Table A-3 Electrical Specifications for the DR Inverter/Charger

a

- 230 Vac/50 Hz Models

Model

DR1512E

DR1524E

DR1548E

DR2424E

Advertising