Calibration problems – Zebra Technologies Z SERIES 79695L-002 User Manual

Page 122

Advertising
background image

Troubleshooting
Calibration Problems

122

79695L-002 Rev. A

Z Series

®

/RZ™ Series User Guide

6/6/08

Calibration Problems

Table 18

identifies problems with calibration, the possible causes, and the recommended

solutions.

Table 18 • Calibration Problems

Problem

Possible Cause

Recommended Solution

Loss of printing
registration on labels.
Excessive vertical
drift in top-of-form
registration.

The platen roller is dirty.

Clean the platen roller according to the
instructions in

Clean the Printhead and Platen

Roller on page 104

.

Media guides are positioned
improperly.

Ensure that the media guides are properly
positioned.

The media type is set
incorrectly.

Set the printer for the correct media type
(gap/notch, continuous, or mark). See

Set Media

Type on page 73

.

The media is loaded incorrectly.

Load media correctly. See

Load Media

on page 41

.

Auto Calibrate failed.

Media or ribbon is loaded
incorrectly.

Ensure that media and ribbon are loaded
correctly.

The sensors could not detect the
media or ribbon.

Manually calibrate the printer. See

Calibrate

Media and Ribbon Sensor Sensitivity on page 83

.

The sensors are dirty or
positioned improperly. The
sensors are dirty, or media is
positioned improperly for the
sensors to detect.

Ensure that the sensors are clean and that media
is positioned properly.

The media type is set
incorrectly.

Set the printer for the correct media type
(gap/notch, continuous, or mark). See

Set Media

Type on page 73

.