Configuration
Standard Control Panel Parameters

88

79695L-002 Rev. A

Z Series

®

/RZ™ Series User Guide

6/6/08

ZPL only

Set Delimiter Character
The delimiter character is a two-digit hex value used as a parameter place
marker in ZPL/ZPL II format instructions. See the ZPL Programming
Guide
for more information.

Note •

Do not use the same hex value for the control, format, and

delimiter character. The printer must see different characters to
work properly.

Default Value: 2C ,

Range: 00 to FF

To change the value shown:

1.

Press

SELECT

to select the parameter.

2.

Press

MINUS (-)

to move to the next digit position.

3.

Press

PLUS (+)

to increase the value of the digit.

4.

Press

SELECT

to accept any changes and deselect the parameter.

ZPL only

Select ZPL Mode
The printer remains in the selected mode until it is changed by this
parameter or by using a ZPL/ZPL II command. The printer accepts label
formats written in either ZPL or ZPL II, eliminating the need to rewrite any
ZPL formats that already exist. See the ZPL Programming Guide for more
information on the differences between ZPL and ZPL II.

Default Value: ZPL II

Range: ZPL II, ZPL

To change the value shown:

1.

Press

SELECT

to select the parameter.

2.

Press

PLUS (+)

or

MINUS (-)

to toggle between the options.

3.

Press

SELECT

to accept any changes and deselect the parameter.

Table 12 • Printer Parameters (Page 20 of 26)

Language/Parameter

Action/Explanation