Calibrate the printer, Auto calibration, Manual calibration – Zebra Technologies Z SERIES 79695L-002 User Manual

Page 60: Auto calibration manual calibration

Advertising
background image

Operations
Calibrate the Printer

60

79695L-002 Rev. A

Z Series

®

/RZ™ Series User Guide

6/6/08

Calibrate the Printer

The printer can be set to calibrate automatically, or you can calibrate it manually.

Auto Calibration

When the control panel setting for

MEDIA POWER UP

or

HEAD CLOSE

is set to

CALIBRATION

, the printer automatically calibrates on power up or when the printhead is

closed. During auto calibration, the printer determines the label length and sensor settings. The
results of the auto calibration are stored in the printer’s memory and are retained even if printer
power is removed. These parameters remain in effect until the next calibration is performed.

Manual Calibration

Perform a media and ribbon sensor calibration to reset the sensitivity of the sensors so the
media and ribbon are detected more accurately. If you change the type of ribbon or media,
your printer may operate better if you perform this calibration.

For instructions, refer to

Calibrate Media and Ribbon Sensor Sensitivity on page 83

.

Note •

If the control panel settings for

MEDIA POWER UP

or

HEAD CLOSE

are set to

LENGTH, NO MOTION, or FEED, the printer starts printing without auto calibrating. See

Select Media Power-Up Option on page 89

or

Select Head Close Option on page 89

.

Advertising