Zebra Technologies Z SERIES 79695L-002 User Manual

Page 92

Advertising
background image

Configuration
Standard Control Panel Parameters

92

79695L-002 Rev. A

Z Series

®

/RZ™ Series User Guide

6/6/08

See next column

View Sensor Settings
These parameters are automatically set during the calibration procedure
and should be changed only by a qualified service technician. Refer to the
ZPL II Programming Guide for information on these parameters.

To skip these parameters:

1.

Press

PLUS (+)

to skip each of the following parameters:

ZPL only

Select Format Convert
Selects the bitmap scaling factor. The first number is the original dots per
inch (dpi) value; the second, the dpi to which you would like to scale.

Default Value: NONE

Selections: NONE, 150

→ 300, 150 → 600, 200 → 600, 300 → 600

To change the value shown:

1.

Press

SELECT

to select the parameter.

2.

Press

PLUS (+)

or

MINUS (-)

to scroll through the options.

3.

Press

SELECT

to accept any changes and deselect the parameter.

Table 12 • Printer Parameters (Page 24 of 26)

Language/Parameter

Action/Explanation

Advertising