Quad charger cycle times – Zebra Technologies ZEBRA QL UMAN-QLP-001 User Manual

Page 16

Advertising
background image

16

QL Plus Series User Guide

rectly under the battery being charged will turn on if the
battery is properly inserted.

The indicators under the battery will allow you to monitor

the charging process per the table below:

Amber

Green

Battery Status

On

Off

Charging

On

Flashing

80% charged (O.K.
to use)

Off

On

Completely
Charged

Flashing

Off

Fault

Important • A fault condition is caused by a problem with the battery.

The charger may indicate a fault because the battery is too hot or cold

to charge reliably. Try to charge the battery again when it returns to

the room’s ambient temperature. If the amber indicator starts flashing

on the second attempt, the battery should be discarded. Always

dispose of batteries in a proper manner as described in Appendix E.

Quad Charger Cycle Times :

Battery

Status

QL 220Plus &

QL 320 Plus

QL 420

Plus

Battery 80%

Charged

1.25 Hrs.

2.5 Hrs.

Battery Fully

Charged

2.5 Hrs.

5 Hrs.

Note • These times are for completely discharged batteries.

Battery packs which are only partially discharged will take

less time to reach their charged state. Batteries which have
reached 80% of their charge capacity may be used, however,
it is recommended that you allow the batteries to reach a full
charge to maintain maximum battery life.

The UCLI72-4 Quad Charger has a safety feature which stops charging

a battery after six hours regardless of its charge state.

Advertising