Communications ports, Rs-232c – Zebra Technologies ZEBRA QL UMAN-QLP-001 User Manual

Page 70

Advertising
background image

70

QL Plus Series User Guide

Communications Ports

RS-232C

Pin#

Signal Name

Type

Description

1

RXD

input

Receive Data

2

TXD

output

Transmit Data

3

CTS

input

Clear To Send from host

4

RTS

output

Request To Send set high when
printer is ready to accept a
command or data

5

GND

Ground

6

NC

No Connect

7

DSR

input

Data Set Ready: low to high
transition turns printer on, high to
low transition turns printer off (if
enabled)

8

DTR

output

Data Terminal Ready: set high when
printer is on.
Set to battery voltage for “S”
versions (compatible with Symbol™
PIM)

8

7

6

4

2

1

5

3

Figure 27: RS-232C Communications Port (8 pin Circular DIN)

Advertising