Xilinx IP Ethernet AVB Endpoint v2.4 UG492 User Manual

Page 64

Advertising
background image

64

www.xilinx.com

Ethernet AVB Endpoint User Guide

UG492 September 21, 2010

Chapter 6: Ethernet AVB Endpoint Transmission

hiLimit

The general equation is:

hiLimitValue = 2000 x idleSlopeValue

In this general equation, the value of 2000 is obtained from the maximum number of bytes
which may be present in legacy frames (an Envelope frame as defined in IEEE802.3 can be of
size 2000 bytes).

In this example, dedicating up to 75% of the total bandwidth to the AV traffic, we obtain:

hiLimitValue = 2000 x 6144 = 12288000

loLimit

The general equation is:

loLimitValue = 1518 x sendSlopeValue

In this general equation, the value of 1518 is obtained from the maximum number of bytes
which may be present in AV frames.

In this example, dedicating up to 75% of the total bandwidth to the AV traffic, we obtain:

loLimitValue = 1518 x 2048 = 3108864