Using the recall safe function, P. 148), Ations – Yamaha M7CL-32 User Manual

Page 148: E function

Advertising
background image

M7CL Owner’s Manual

Using the Recall Safe function

148

“Recall Safe” is a function that excludes only specific parameters/channels (DCA groups) from
Recall operations. This differs from the Focus settings (

→ p. 147) made for individual scenes in

that Recall Safe settings are common to all scenes.

1

In the function access area, press the CH
JOB button to access the CH JOB popup
window.

2

Press the RECALL SAFE button to access
the RECALL SAFE MODE popup window.

In this popup window you can make settings for the
Recall Safe function. The window contains the follow-
ing items.

1 CH RECALL SAFE field

The channels and DCA groups for which Recall Safe
is turned on are highlighted in this field. If you turn on
the SET BY SEL button, you can turn on Recall Safe
for a channel or DCA group simply by pressing the
[SEL] key of that channel or DCA group.

B CLEAR ALL button

This clears all Recall Safe settings for the channels or
DCA groups that are highlighted in the CH RECALL
SAFE field.

C GLOBAL RECALL SAFE field

Press the buttons in this field to select the global
parameters (i.e., parameters that apply to the entire
mix, rather than to specific channels) that will be set to
Recall Safe.

D SAFE PARAMETER SELECT field

Here you can switch Recall Safe on/off for the desired
channels or DCA groups, and choose the parameters
that will be excluded from Recall operations. The
channel or DCA group you selected by pressing its
[SEL] key will be shown in this field as the target of
your operations. If you press any of the [SEL] keys of
the DCA groups, the parameters for DCA groups 1–8
will be shown simultaneously.

E APPLY TO ALL INPUT button / APPLY TO

ALL OUTPUT button

If these buttons are on when you operate the SAFE
PARAMETER SELECT buttons, the changes will
apply to all input (or output) channels. This is conve-
nient when you want to make settings for all channels
together.

3

To select the channel or DCA group whose
Recall Safe settings you want to edit, press
the corresponding [SEL] key.

The corresponding channel or DCA group will be
enclosed by a white frame in the CH RECALL SAFE
field. (However, this white frame does not mean that
the Recall Safe setting is now enabled.) The selected
channel or DCA groups 1–8 will be recalled to the
SAFE PARAMETER SELECT field.

4

If you want to enable Recall Safe for spe-
cific parameters of the selected channel or
DCA group, make the following settings in
the SAFE PARAMETER SELECT field.

Using the Recall Safe function

RECALL SAFE button

1

2

3

4

5

• The RECALL SAFE MODE popup window can also be

accessed from the SELECTED CHANNEL VIEW screen’s
RECALL SAFE field (

p. 95).

HINT

• If the CH RECALL SAFE field’s SET BY SEL button is on,

Recall Safe will be enabled when you press the [SEL] key,
and the corresponding channel or DCA group will be high-
lighted in the CH RECALL SAFE field. You can select param-
eters as described in step 4 even after turning Recall Safe on.

HINT

• Simply selecting a parameter in step 4 does not enable Recall

Safe. To turn Recall Safe on/off, you must also perform the
operation of step 5.

NOTE

• While the APPLY TO ALL INPUT button (or the APPLY TO

ALL OUTPUT button) is on, operations in the SAFE PARAM-
ETER SELECT field will apply to all input channels (or output
channels).

HINT

Advertising
This manual is related to the following products: