User Level settings

M7CL Owner’s Manual

User settings (Secur

ity)

18

213

3

Press the USER LEVEL tab to access the
USER LEVEL page.

If you are logged-in as the Administrator, you can
switch to the USER LEVEL for GUEST page, and
view or change the user level of the Guest account.

This page includes the following items.

1 CH OPERATION

Here you can specify (for each channel) the operations
that will be permitted for input channels, output chan-
nels, and DCA groups. The settings will apply to the
currently selected channel. Settings for currently-
selected channels will be displayed below the CH
OPERATION section. Use the panel [SEL] keys or the
Selected Channel field in the function access area to
select the channel for which you want to make set-
tings.

• HA...................Restricts operation of the HA (Head

Amp) patched to that channel.

• PROCESSING

...........Restricts operation of all signal pro-

cessing parameters for that channel
(except for fader, [ON] key, send
level, etc.)

• FADER / ON ...Restricts operation of that channel’s

fader, [ON] key, send level, etc.

• SET BY SEL ...If this button is on, a group of multi-

ple channels can be set to the same
settings in a single operation. To
select channels, turn this button on,
and then press the [SEL] keys of the
desired channels on the panel. If
you change the setting of any chan-
nel in the group, the change will
affect all channels in the group.
Channels that have the same set-
tings are shown with the same color
in the channel display field.

B CURRENT SCENE

This specifies the operations that can be performed on
the current scene memory.

• INPUT PATCH / NAME

...........Operations for input channel patch-

ing and names will be restricted.

• OUTPUT PATCH / NAME

...........Operations for output channel

patching and names will be
restricted.

• BUS SETUP ...Operations for bus setup will be

restricted.

• RACK 1–8 ...... Operations for the racks (1–8) will

be restricted.
However, there will be no restriction
on operating the MIDI CLK button
displayed for delay-type and modu-
lation-type effects, or the PLAY/REC
button displayed for the FREEZE
effect.

• MUTE GROUP ASSIGN / MASTER

........... Operations for mute group assign-

ment and mute group master will be
restricted.

C SCENE LIST

This specifies the operations that can be performed on
scene memories.

• STORE / SORT operations

• RECALL operations

D LIBRARY LIST

This specifies the operations that can be performed on
libraries.

• STORE / CLEAR operations

• RECALL operations

E FILE LOAD

This specifies the types of file that can be loaded from
a USB storage device. The user authentication key
contains the user level, user-defined keys, and prefer-
ence settings. Other data is saved in an “ALL” file.

• USER SETUP (user-defined keys and preference set-

tings)

• SYSTEM SETUP / MONITOR SETUP

• CURRENT SCENE

• SCENE LIST

• LIBRARY LIST

F MONITOR SETUP

This specifies the monitor setup operations that can be
performed.

• OSCILLATOR

• TALKBACK

G SYSTEM SETUP

This specifies the system setup operations that can be
performed.

• MIXER SETUP

• OUTPUT SETUP

• MIDI

• STAGE BOX SETUP

H SET ALL/CLEAR ALL button

This button permits/clears all items.

4

Specify the user level by pressing the but-
ton for each item that will be permitted.

5

When you have finished making settings,
close the popup window and press the
SETUP button in the function access area.

• For the channel parameters included in PROCESSING, refer

to the appendix (p. 277).

HINT