About The XPR Power Supply

Rear Panel Connectors and Switch

Release 1.1

21

Figure 1.4 Programming and Monitoring S1 Switch

(Switch is shown in factory default configuration.)

The rear panel at the switch is labeled with OFF at the top and ON at the bottom. Any
of the eight switches on S1 is OFF when it has been flipped up to break contact, ON
when flipped down to close contact.

Table 1.1

shows the functions assigned to each S1 switch. Factory defaults are

underlined.

Table 1.1 Rear Panel S1 Switch Assignments

Resetting the Switches

Before making any changes to the switch settings, either turn off the AC power
switch or disable the power supply output by pushing the front panel OUT ON/OFF
switch to its IN position. This temporarily shuts down the power supply. The front
panel OFF LED turns on. Then use any small, flat-bladed screwdriver to change the
switch settings.

1 Resistive Programming of Output Voltage

2 Resistive Programming of Output Current Limit

3 Selects Output Voltage Programming and Monitor Range select

4 Selects Output Current Limit Programming and Monitor Range select

5 Selects Output Voltage Control: Local or Remote

6 Selects Output Current Control: Local or Remote

7 Selects Remote Interlock Logic

8 Selects Over Temperature Shutdown Reset Mode

Switch

Function

OFF

ON

S1-1

1 mA current source for resistive programming of
output voltage

Voltage source
programming

Resistive programming
(0-5 k, 0-10 k)

S1-2

1 mA current source for resistive programming of
output current limit

Voltage source
programming

Resistive programming
(0-5 k, 0-10 k)

S1-3

Output voltage programming and monitor range
select

0-5 V (0-5 k)

0-10 V (0-10 k)

S1-4

Output current limit programming and monitor
range select

0-5 V (0-5 k)

0-10 V (0-10 k)

S1-5

Output voltage control mode select

Local Control

Remote Control

S1-6

Output current control mode select

Local Control

Remote Control

S1-7

Remote Interlock logic signal select

Active High=OFF Active Low=OFF

S1-8

Over temperature shutdown reset mode select

Auto reset

Latch OFF