Ac line input specifications, Ac line input voltage operating ranges, Table a.5 – Xantrex Technology XPR 150-40 User Manual

Page 72

Advertising
background image

Specifications and Characteristics
AC Line Input Specifications

70

Operating Manual for XPR Series Power Supply

AC Line Input Specifications

The input to the power supply requires the following specifications.

AC Line Input

Voltage

Operating

Ranges

Table A.5AC Line Input Specifications

Operating Range

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

190 to 242 V

ac

3

φ (3 wire + safety ground)

342 to 500 V

ac

3

φ (3 wire + safety ground)

Frequency Range

47 to 63 Hz

Maximum Peak In-rush Current at turn on 35 A

rms

Minimum Power Factor

1

nominal 208V

rms

(Standard)

nominal 400V

rms

(with HV-Input option)

0.95
0.9

Operating Current

nominal 208V

rms

(Standard)

Maximum

2

Typical

3

24 A
20 A

Operating Current

nominal 400V

rms

(with HV-Input option)

Maximum

4

Typical

5

13 A
11 A

1. At nominal input voltage and maximum power
2. At 190V

ac

input voltage, 55

°

C ambient temperature and maximum power

3. At 208V

ac

input voltage, 25

°

C ambient temperature and maximum power

4. At 342 V

ac

input voltage, 55

°

C ambient temperature and maximum power

5. At 400V

ac

input voltage, 25

°

C ambient temperature and maximum power.