Remote Operation
Remote Monitoring of Output Voltage and Current

64

Operating Manual for XPR Series Power Supply

Remote Monitoring of Output Voltage and Current

Readback

Signals

The J1 connector on the rear panel provides access to calibrated readback signals for
remote monitoring of the output voltage and current. Rear panel switches S1-3 and
S1-4 allow you to select either a 0-5 Vdc or a 0-10 Vdc range for the output. The
readback signal represents 0 to 100% of the power supply's output.

See

Table 4.4

for the required J1 connections and switch settings for remote

monitoring of readback signals with 0-5 Vdc or 0-10 Vdc outputs. Use shielded pair
wiring (20 to 24 AWG) and ground the shield to the chassis.

Table 4.4 Power Supply Settings for Remote Monitoring of Readback Signals

Readback Signal

J1 Connection
Signal (+)

J1 Connection
Return (–)

Switch S1 Setting

Output Voltage
(0-5 Vdc)

J1-4

J1-6

S1-3=

OFF

Output Voltage
(0-10 Vdc)

J1-4

J1-6

S1-3=ON

Output Current
(0-5 Vdc)

J1-5

J1-6

S1-4=

OFF

Output Current
(0-10 Vdc)

J1-5

J1-6

S1-4=ON