background image

About The XPR Power Supply
Rear Panel Connectors and Switch

22

Operating Manual for XPR Series Power Supply

Rear Panel J1

Connector

The J1 Programming and Monitoring connector is a 15-terminal wire clamp
connector located on the power supply’s rear panel. See

Figure 1.5

. The J1 connector

provides access to the following functions:

Remote programming of output voltage AND/OR current limit

Remote monitoring of calibrated readback signals for output voltage and output

current

Remote control of the shutdown function using TTL-compatible signals

(Interlock module)

15 V user supply to allow for contract closure control of the remote on/off line,

current limited

Figure 1.5 Programming and Monitoring J1 Connector

See

Table 1.2, on page 23

for the list of the J1 connector terminal numbers, their

references, and corresponding functions.

1 Output Voltage Programming Input

2 Output Current Limit Programming Input

3 Program Return

4 Output Voltage Monitor

5 Output Current Monitor

6 Monitor Return

7 N/C

8 Ground Return

9 + 15 V User Signal

10 N/C

11 Interlock Return (–)

12 Interlock Signal (+)

13 N/C

14 Shutdown Return (–)

15 Shutdown (+)