Operation

Alarms

Release 1.1

57

Alarms

The possible alarms are:

AC - AC Input is out of range, non-latching shutdown

OTP - Internal over temperature condition, latching or non-latching, S1 selects

INT - External interlock is active (see Interlock

page 53

)

OVP - Output over voltage condition, latching shutdown

SNS - Output remote sense line fault, latching shutdown

These conditions have corresponding indicator LEDs on the front panel (see

Figure 1.1, on page 18

and

Figure 1.2, on page 19

.)

WARNING- Fire Hazard
If an over-voltage, over-current, or over-power protection error persists without

apparent cause, press OUT ON/OFF button to disable the output, and turn the AC

switch OFF. Inspect the load and power supply for evidence of an electrical fault. The

power supply should not be brought back into operation if there is any evidence of an

electrical fire or other safety hazards.