Specifications and Characteristics
Output Performance Specifications

74

Operating Manual for XPR Series Power Supply

Fall Time

For a programmed 95% to 5% step in output voltage.

Time Delay From Power On Until Output Stable

5 s maximum
(Within regulation envelope)

Time Delay From Output Enable Until Output Stable

2 s maximum
(Within regulation envelope)

Output Hold-Up Time – Power Off

Minimum 4 ms (at full load)

Output Hold-Up Time – Source Interruption

Minimum 4 ms with output deviation less than 5% of maximum output voltage after
source interruption.

Transient Response Time

1

Time to recover within 0.75% of rated output of previous level after step change in
load current between 50% and 100%.

Mode Crossover

Maximum deviation as a percentage of rated output voltage.

Peak–Peak and RMS Noise Bandwidth Limits

The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.
The frequency range for RMS measurements is 10 Hz–100 kHz.

Load Condition

Time (Max)

No Load

3 s

Full Load

50 ms

1. Time for the output voltage to recover within 0.75% of rated output of its previous level

after a step change in load current of up to 50% - 100% and 100% to 50% of rated

output

Mode

Time

Voltage Mode

3 ms

CV – CC Overshoot

1%