Specifications and Characteristics
Output Performance Specifications

72

Operating Manual for XPR Series Power Supply

Programming Accuracy

1

Readback Accuracy

30 Minute Drift

2

8 Hour Drift Temperature Stability

3

Temperature Coefficients

Remote Analog Programming Interface

Voltage Programming
Resistive Programming

1% of V or Imax
2% of V or Imax

1. Accuracy specifications apply for settings in range of 1% to 100% of rated output

Front Panel or Remote Analog Programming Interface

Voltage Readback
Current Readback

1% of Vmax
1% of Imax

Voltage

0.04% of Vmax

Current

0.6% of Imax

2. At 25°C ±5°C, with full power load

Voltage

0.02% of Vmax

Current

0.04% of Imax

3. At 25°C ±5°C after 30 minutes full load operation

Front Panel or Analog Programming Interface

Voltage Programming
Current Programming
Voltage Readback
Current Readback

0.04% of Vmax

/°C

0.06% of Imax

/°C

0.04% of Vmax

/°C

0.06% of Imax

/°C