Positioning the media sensor – Zebra Technologies ZEBRA Z4M H-974 User Manual

Page 5

Advertising
background image

H-974

PAGE 5 OF 57

0808 IH-974

Positioning the Media Sensor

The correct positioning of the media sensor is important. It can make the difference
between a perfect label and a call to Technical Support!

There are two media sensors in this printer: “reflective” and “transmissive.”

Reflective Sensor

The reflective sensor detects the “start-of-label indicator” (the notch, hole, black
mark, or gap between die-cut labels).

The reflective sensor must be positioned:

directly under the notch, hole, or black mark, or

anywhere along the width of the media if there is a gap between labels

The glow of the red light through the media will help you to accurately position the
reflective sensor.

NOTE: If you are using continuous media, position the reflective
sensor anywhere under the media so that the printer can detect an
out-of-paper condition.

NOTE: The reflective sensor is compatible with most types of media.
However, if you encounter difficulties with calibration, use the
transmissive sensor. See “Transmissive Sensor” on page 12.

10

Zebra Z4M Printer User’s Guide

Advertising