Error condition HEAD OPEN

Error condition RIBBON IN

Warning HEAD OVER TEMP

Warning HEAD UNDER TEMP

68

Zebra Z4M Printer User’s Guide

Problem

Solution

The printhead is not fully closed.

Close the printhead.

The ribbon is loaded incorrectly; it is
covering the head open sensor.

Correctly align the ribbon with the guide mark on the
ribbon guide plate before closing the printhead
assembly. See “Ribbon Loading” on page 34.

Problem

Solution

Print method is incorrectly set.

Via the front panel, locate the “PRINT METHOD” menu
item (page 42) and select thermal transfer mode.

Ensure that the printer driver and/or software settings
are correctly set (if applicable).

The ribbon is loaded.

Remove the ribbon and set the printer to direct thermal
mode. (See “PRINT METHOD” on page 42.)

Ensure that the printer driver and/or software settings
are correctly set (if applicable).

Problem

Solution

The printhead is over temperature.

Allow the printer to cool. Printing automatically resumes
when the printhead elements cool to an acceptable
operating temperature.

Problem

Solution

The printhead is under temperature.

Continue printing while the printhead reaches the
correct operating temperature.

The environment may be too cold for proper printing.
Relocate the printer to a warmer area.