VEGA VEGAPULS 56K User Manual

Page 33

Advertising
background image

VEGAPULS 56K

33

22915-EN-041227

2

-

+

4 ... 20 mA

2

4

2

2

> 250

1)

Measuring system with VEGAPULS 56K in four-wire technology

• Four-wire technology, power supply and output signal via two separate two-wire cables.
• Output signal 4 … 20 mA active.
• Optional external indicating instrument with analogue and digital indication (can be mounted

up to 25 m away from the sensor).

• Adjustment with PC, HART

®

handheld or adjustment module MINICOM (can be plugged into

the sensor or into the indicating instrument VEGADIS 50)

• Max. load 500

Electrical connection

active

2)

VEGADIS 50

1)

If the resistance of the processing
systems connected to the
4 … 20 mA signal output is less
than 200

Ω, a resistor must be

connected to the connection cable
during adjustment to get a loop
resistance of 250

Ω up to 350 Ω .

The digital adjustment signal would
otherwise be severely damped or
short-circuited due to insufficient
resistance of the connected
processing system. Digital
communication with the PC would
not be ensured.

2)

4 … 20 mA active means that the
sensor delivers a level-dependent
current of 4 … 20 mA (source).
The sensor reacts electrically in
the processing system (e.g.
indication) like a current source.

HART

®

handheld

VEGA-
CONNECT 2

Advertising