Flange dimensions acc. to ansi – VEGA VEGAPULS 56K User Manual
Page 56
56
VEGAPULS 56K
22915-EN-041227
Flange dimensions acc. to ANSI
D = outer flange diameter
b = flange thickness
k
= diameter of hole circle
d
1
= seal ledge diameter
f
= seal ledge thickness
1
/
16
" = approx. 1.6 mm
d
2
= diameter of holes
External indicating instrument VEGADIS 50
Adjustment module MINICOM
Mounting on carrier rail 35 x 7.5 acc. to EN 50 022 or flat
screwed
Adjustment module for insertion into sensors
or into the external indicating instrument
VEGADIS 50
Size
Flange
Seal ledge
Holes
D
b
k
d
1
No.
d
2
2" 150 psi
152.4
19.0
120.7
91.9
4
19.1
3" 150 psi
190.5
23.8
152.4
127.0
4
19.1
4" 150 psi
228.6
23.8
190.5
157.2
8
19.1
6" 150 psi
279.4
25.4
241.3
215.9
8
22.4
Technical data
;;;;;;;;;;;;;
;;;;;;;;;;;;;
;;;;;;;;;;;;;
;;
;;
;;
;;
;;
;;
f
d
b
d
k
D
2
1
82
Pg 13,5
118
108
135
38
85
ù5
10
48
Note:
The diameter of the connection cable should be min.
5 mm and max. 9 mm.
Otherwise the seal effect of the cable entry would not
be ensured.
-
+
ESC
OK
Tank 1
m (d)
12.345
74
32,5
67,5