VEGA VEGAPULS 56K User Manual

Page 52

Advertising
background image

52

VEGAPULS 56K

22915-EN-041227

Technical data

Outputs and processing

Display

Indication

- optionally mounted, scalable analogue and

digital measured value display.

- optional external measured value display

which can be mounted up to 25 m away from
the sensor, measured value display powered
by the sensor

Signal output

Signal output
- two-wire technology

4 … 20 mA

- four-wire technology

4 … 20 mA

Resolution of the 20 mA signal

1.6 µA (0.01 % of operating range)

Load
- four-wire

0 … 500

- two-wire

see load diagram under „Power supply“

Integration time

0 … 999 seconds

Two-wire technology 4 … 20 mA:
The analogue 4 … 20 mA output signal (measuring signal) is transmitted together with the
power supply via one two-wire cable.

Four-wire technology 4 … 20 mA:
Separate power supply. The analogue 4 … 20 mA output signal (measuring signal) is trans-
mitted in a cable separate from power supply.

Advertising