VEGA VEGAPULS 56K User Manual
Page 47
VEGAPULS 56K
47
22915-EN-041227
PN 16
PN 25
PN 40
PN 64
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
64
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
PN 16
PN 25
PN 40
Flange DIN DN 50
Material: 1.4571
Groove and tongue acc.
to DIN 2512 Form F, N
Flange DIN DN 80
Material: 1.4571
Seal surface acc. to DIN
2526 Form B, C, D, E
bar
40
25
16
-40
0
50
100
150
200
250
300
350
˚C
PN 16
PN 25
PN 40
Flange DIN DN 50
Material: 1.4571
Seal surface acc. to DIN
2526 Form B, C, D, E
Ambient conditions
Ambient temperature on the housing
-20°C … +60°C
Flange temperature (process temp.)
-40°C … +350°C (pressure-dependent), see
following diagrams
Vessel installation
with process temperatures > 200°C the rear of
the flange must be covered with a heat insulation
see chapter „4 Mounting and installation“
Storage and transport temperature
-40°C … +80°C
Protection
IP 66/IP 67
Protection class
- two-wire sensor
II
- four-wire sensor
I
Overvoltage category
III
Vessel pressure
max. 64 bar (temperature-dependent), see
following diagrams
Technical data