VEGA VEGAPULS 56K User Manual

Page 46

Advertising
background image

46

VEGAPULS 56K

22915-EN-041227

Accuracy

1)

(typical values under reference conditions, all statements relate to the nominal measuring
range)

Influence
- of the ambient temperature

1)

0.06 %/10 K

- of the process temperature

1)

negligible (0.004 %/10 K at 5 bar)
(0.003 %/10 K at 40 bar)

- of the process pressure

21

negligible (0.025 %/bar)

Resolution

1 mm

Resolution of the output signal

1.6 µA, 0,01 % or 1 mm

Accuracy

see diagram

Adjustment time

> 2 s (dependent on the parameter adjustment)

Characteristics

Frequency

5.8 GHz (USA 6.3 GHz)

Intervals
- two-wire sensor

0.6 s

- four-wire sensor

0.3 s

Min. span between full
and empty adjustment
- analogue output signal

10 mm (recommended 50 mm)

- digital output signal

5 mm (recommended 50 mm)

Beam angle (at –3 dB)
- with DN 80

38° (only for standpipe measurement)

- with DN 100

30° (only for standpipe measurement)

- with DN 150

20°

- with DN 200

16°

- with DN 250

14°

Technical data

1)

Reference conditions acc. to IEC 770

1,0 m

30 m

20 mm

10 mm

-10 mm

-20 mm

Advertising