VEGA Modbus-TCP, ASCII protocol User Manual

Page 13

Advertising
background image

13

2 ASCII protocol

Modbus-TCP, ASCII protocol • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62

30768-EN-130701

End identification: Carriage Return CR (1 sign)

Total length of the telegram: 2 characters
"N"-times repetition of the following telegram

(N=total number of assigned PC/DCS outputs)

Number of bytes

Character

T1

1

=

DCS no.

3

001 … 030

T2

1

#

Value

5 … 6

-067.3

T3

1

%

End identification

1

CR

T1: "=" (1 character)

DCS no.: No. of the PC/DCS output as 3-digit decimal number

T2: "#" (1 character)

Value: Numerical value of the PC/DCS output or with interferred

measured value the text "FAULT"

Formatting of the value:

Character

Meaning

1

"- ": Minus with negative numbers
" ": Space with positive numbers

2 … 4

3-digit number

5

".": Decimal point

6

1-digit number (after the decimal point)

T3: "%" (1 character)

End identification: Carriage Return CR (1 sign)

Total length of the telegram: N*12 … 13 characters
Note:

The % sign is a separator, not the unit %
Enquiry:

%
Answer:

=001# 067.3%

=002# 824.6%

=003#-067.3%

=004# 824.6%

% Block enquiry with length

As answer to the range enquiry, the range stated in the enquiry with

PC/DCS values is delivered. The measured value is transmitted with

three decimal places in front of the decimal point and one decimal

place after the decimal point without unit.

Reply from the signal

conditioning instrument

Example:

Advertising