4 Mounting

VEGASOURCE 35 •

38132-EN-130415

If there are gaps or intervening spaces around the installation, provide

protective fences or grids to keep hands away from the dangerous

area. Such areas must be marked accordingly.

α/2

α

Fig. 11: Orientation - Source holder
a Angle of aperture

For level detection, the version of the source container with an exit

angle of a = 5° is suitable. The radiation must be directed exactly

towards the detector mounted on the opposite side.
If you want to use larger exit angles (20° or 40°), you have to make

sure the beam is horizontal. To do this you have to mount the source

container so that the eye-bolt is in a horizontal position.
The source container VEGASOURCE should be mounted as close as

possible to the vessel.
However, a distance can often not be avoided with large measuring

ranges and small vessel diameters.
If there are gaps or intervening spaces around the installation, provide

protective fences or grids to keep hands away from the dangerous

area. Such areas must be marked accordingly.

Orientation - Limit level

measurement