VEGA VEGASOURCE 35 User Manual

Page 33

Advertising
background image

33

6 Setup

VEGASOURCE 35 •

38132-EN-130415

Switching off the radiation is carried out analogously to this proce-

dure. To switch off the radiation, turn the stirrup (6) 180° clockwise.

6.3 Operation VEGASOURCE 35 - version C

Warning:

Make sure before switching on the radiation that no persons are

inside the radiation areas (also not inside the vessel).
Radiation must only be switched on by trained personnel.

The figures in brackets refer to the following illustration.

180°

1

4

2

3

2

1

Fig. 25: Switching the radiation on - VEGASOURCE 35 version C
1 Padlock

2 Locking screw

3 Holding pin

4 Swivel bracket

Initial situation: Source holder is in position OFF

Remove padlock (1)

Loosen locking screw (2)

Warning:

Do not remove the seal. Do not push the sealed pin (3). Turning the in-

sert over the pin (3) leads to the removal position of the source insert.

Turn stirrup (4) 180° anticlockwise

Note:

The actual switch position is shown by the visible label (ON or OFF).

The other label is always covered by the stirrup.

Secure the switch position ON with the padlock (1) in the specified

position

Tighten locking screw (2)

Switching the radiation

off

Switching the radiation

on