2 operation vegasource 35 - version b – VEGA VEGASOURCE 35 User Manual

Page 31

Advertising
background image

31

6 Setup

VEGASOURCE 35 •

38132-EN-130415

The respective switch position is shown by a marking arrow (ON

or OFF)

9. Do not loosen the seal.

Warning:

Do not push the sealed pin (9). Turning the insert over the pin leads to

the removal position of the source insert.
10. Insert key lock with key
11. Turn key lock with key approx. 45° clockwise
12. If available: Screw in the pin with a hexagon spanner (spanner

size 5)

13. Place the protective cover back on

The source holder must not operated without protective cover.

Radiation ON

The label EIN - ON is visible. The marking arrow points to EIN - ON.
Radiation OFF

The label AUS - OFF is visible. The marking arrow points to AUS -

OFF.

Switching off the radiation is carried out analogously to this proce-

dure. To switch off the radiation, turn the source insert 180° clockwise.

6.2 Operation VEGASOURCE 35 - version B

Warning:

Make sure before switching on the radiation that no persons are

inside the radiation areas (also not inside the vessel).
Radiation must only be switched on by trained personnel.

The figures in brackets refer to the following illustration.

Indication of the switch-

ing status

Switching the radiation

off

Switching the radiation

on