VEGA MINITRAC 31 Profibus PA User Manual

Page 47

Advertising
background image

47

6 Set up with the display and adjustment module

MINITRAC 31 • Profibus PA

43836-EN-131119

In this menu item you can activate the relay output and determine its

function as well as the switching points.
When the output of the process values is set, you can choose be-

tween overfill and dry run protection.
The relay outputs of the sensor react accordingly.
The following reference values can be selected:

None - Relay operates as fail safe relay

Electronics temperature

Process value

"No" reference value means that the relay output operates as fail safe

relay.

Push the [->] button, to reach the relay settings.
Example for the adjustment of the process value
First of all select the requested mode (overfill or dry run protection).

Caution:

Independent of the selected reference value, the relay will deenergize

in case of failure.

With this menu item you safeguard the sensor parameters against

unauthorized or unintentional modifications.
This menu item is described in the operating instructions manual

"Display and adjustment module".
Display

With this parameter you can change the display language.

This parameter is described in the operating instructions manual

"Display and adjustment module".

With this parameter you can change the indication of the display.

Setup - Relay

Lock setup - adjustment

Display - Language

Display - Displayed value