VEGA MINITRAC 31 Profibus PA User Manual

Page 60

Advertising
background image

60

6 Set up with the display and adjustment module

MINITRAC 31 • Profibus PA

43836-EN-131119

The following reset functions are available:
Basic settings: Resetting of the parameter adjustments to default

values at the time of shipment. Order-specific settings are deleted.
Default settings: Resetting of the parameter adjustment like under

"Basic settings". In addition, special parameters are reset to default

values. Order-specific settings are deleted.
Peak values of measured value: Resetting of the parameter adjust-

ments in the menu item "Setup" to the default values of the respective

instrument. Order-specific settings remain but are not taken over into

the current parameters.
Peak values of temperature: Resetting of the measured min. and

max. temperatures to the actual measured value.
The following table shows the default values of the instrument. The

values apply for the application "Level". First of all you have to select

the application.
Depending on the instrument version, not all menu items may be

available or they may be differently assigned:

Menu

Menu item

Default value

Setup

Sensor address

126

Measurement loop name

Sensor

Isotope

Cs-137

Application

Limit level

Background radiation

0 ct/s

Temperature unit

° C

Adjustment mode

1-point

Adjustment (uncovered)

90000 ct/s

Delta I

90 %

AI FB1 Channel

Process value

AI FB1 scaling unit

%

AI FB1 scaling

0 % = 0 %
100 % = 100 %

AI FB1 damping

0 s

Mode relay

Dry run protection

Block adjustment

Released

Display

Language

Selected language

Displayed value

Pulse rate (ct/s)

With this function

Additional adjustments -

Copy instrument settings

Advertising