VEGA MINITRAC 31 Profibus PA User Manual

Page 66

Advertising
background image

66

6 Set up with the display and adjustment module

MINITRAC 31 • Profibus PA

43836-EN-131119

If a hardware address was adjusted (< 126), then the instrument

signals that the hardware address is active.

Here you can assign a suitable measurement loop name. Push the

"OK" key to start the processing. With the "+" key you change the sign

and with the "->" key you jump to the next position.
You can enter names with max. 19 characters. The character set

comprises:

Capital letters from A … Z

Numbers from 0 … 9

Special characters + - / _ blanks

In this menu item you can adjust the MINITRAC 31 to the integrated

isotope in the source container.
For this purpose, check which isotope is integrated in the source

container. You can find this information on the type label of the source

container.

With this selection, the sensitivity of the sensor is adapted in an opti-

mum way to the isotope.
The MINITRAC 31 requires this information for the decay compensa-

tion. An annual recalibration is hence not necessary.
Enter the requested parameters via the appropriate keys, save your

settings with [OK] and jump to the next menu item with the [ESC] and

the [->] key.

Enter here, the respective application.
This menu item enables adaptation of the sensor to the requested ap-

plication. You can choose between the following applications: "Level",

"Density", "Limit level", "X-ray alarm" or "Real value correction".

With this menu item you safeguard the sensor parameters against

unauthorized or unintentional modifications.

Setup - Measurement

loop name

Setup - Isotope

Setup - Application

Lock setup - adjustment

Advertising