VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Profibus PA Approval according to LPR radio standard User Manual

Page 70

Advertising
background image

-

Parabolic antenna

1 g at 5 … 200 Hz according to EN60068-2-6
(vibration with resonance)

Shock resistance

-

Horn antenna

100 g, 6 ms according to EN60068-2-27 (mechan-
ical shock)

-

Parabolic antenna

25 g, 6 ms according to EN60068-2-27 (mechanical
shock)

Data on rinsing air connection

Pressure max.

6 bar (87.02 psig)

Air quantity without reflux valve, with

-

0.2 bar (2.9 psig)

2.0 m

3

/h

-

0.5 bar (7.25 psig)

3.5 m

3

/h

-

1 bar (14.5 psig)

4.5 m

3

/h

-

1.5 bar (21.76 psig)

5 m

3

/h

-

2 bar (29.0 psig)

5.5 m

3

/h

Thread

G⅛ A

Closure, with

-

Non-Ex

Dust protection cover of PE

-

Ex

Threaded plug of 316Ti

Reflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex
version)

-

Material

316Ti

-

Seal

FKM (Viton), FFKM (Kalrez 6375)

-

for tube diameter

6 mm

-

opening pressure

0.5 bar (7.25 psig)

-

Nominal pressure stage

PN

250

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

Cable entry/plug

6)

-

Single chamber housing

l

1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5

or:

l

1 x closing cap M20 x 1.5; 1 x blind stopper
M

20 x 1.5

or:

l

1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5

6)

Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.