VEGA VEGAFLEX 81 HART - integrated accumulator User Manual

Page 11

Advertising
background image

11

3 Product description

VEGAFLEX 81 • HART - integrated accumulator

44640-EN-130430

This operating instructions manual applies to the following instrument

versions:

Hardware from 1.0.0

Software from 1.0.0

Only for instrument versions without SIL qualification

The instrument and the electronics version can be determined via the

product code on the type label as well as on the electronics.

Standard electronics: Type FX80H.-

The scope of delivery encompasses:

Sensor with integrated accumulator

Battery charger

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Operating instructions manual "Display and adjustment mod-

ule" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAFLEX 81 is a level sensor with cable or rod probe for

continuous level or interface measurement, suitable for applications

in liquids.

High frequency microwave pulses are guided along a steel cable or

a rod. Upon reaching the product surface, the microwave pulses are

reflected. The running time is evaluated by the instrument and output-

ted as level.

d

h

1

Fig. 5: Level measurement
1 Sensor reference plane (seal surface of the process fitting)

d Distance to the interface (HART value 1)

h Height - Level

Scope of this operating

instructions manual

Versions

Scope of delivery

Application area

Functional principle -

level measurement