68

11 Supplement

VEGABAR 83 • Profibus PA

45037-EN-131107

Nominal measuring range in bar/

kPa

Nominal measuring

range in psig

In the compensated

temperature range

In the non-compen-

sated temperature

range

0 … 1 bar/0 … 100 kPa

0 … 15 psig

< {0.1 % + 0.2 x

(0.5+0.5 x TD)}

< {0.1 % + 0.3 x

(0.5+0.5 x TD)}

0 … 2.5 bar/0 … 250 kPa

0 … 35 psig

-0.5 … 0.5 bar/-50 … 50 kPa

-7 … 7 psig

-0.2 … 0.2 bar/-20 … 20 kPa

-3 … 3 psig

< {0.15 % + 0.4 x

(0.5+0.5 x TD)}

< {0.15 % + 0.6 x

(0.5+0.5 x TD)}

0 … 0.4 bar/0 … 40 kPa

0 … 6 psig

Long-term stability (according to DIN 16086 and IEC 60770-1)
Specifications refer to the set span. Turn down (TD) is the ratio: nominal measuring range/set span.

Ceramic/metal measuring cell

Piezoresistive/strain gauge

measuring cell

One year

< 0.05 % x TD

< 0.1 % x TD

Five years

< 0.1 % x TD

Ten years

< 0.2 % x TD

Ambient conditions

Version

Ambient temperature

Storage and transport temper-

ature

Standard version

-40 … +80 °C (-40 … +176 °F)

-60 … +80 °C (-76 … +176 °F)

Version IP 66/IP 68 (1 bar)

-20 … +80 °C (-4 … +176 °F)

-20 … +80 °C (-4 … +176 °F)

Version IP 68 (25 bar) with connec-

tion cable PUR

-20 … +80 °C (-4 … +176 °F)

-20 … +80 °C (-4 … +176 °F)

Version IP 68 (25 bar), connection

cable PE

-20 … +60 °C (-4 … +140 °F)

-20 … +60 °C (-4 … +140 °F)

Process conditions
Product temperature piezoresistive/strain gauge measuring cell

Seal

Standard

Extended temperature

range

Version for oxygen ap-

plications

Without sealing (with pro-

cess fitting according to

EN 837)

-40 … +105 °C (-

40 … +221 °F)

-

-40 … +60 °C (-

40 … +140 °F)

FKM (VP2/A)

-20 … +105 °C (-

4 … +221 °F)

-20 … +150 °C (-

4 … +302 °F)

-20 … +60 °C

(+4 … +140 °F)

EPDM(A+P 75,5/KW75F) -30 … +105 °C (-

22 … +221 °F)

-30 … +150 °C (-

22 … +302 °F)

-30 … +60 °C (-

22 … +140 °F)

FFKM (Perlast G75S)

-15 … +105 °C

(+5 … +221 °F

-15 … +150 °C

(+5 … +302 °F)

-15 … +60 °C

(+5 … +140 °F)

FEPM (Fluoraz SD890)

-5 … +105 °C

(+23 … +221 °F)

-

-5 … +60 °C

(+23 … +140 °F)

Product temperature METEC

®

measuring cell