2 communication profibus pa – VEGA VEGABAR 83 Profibus PA - Operating Instructions User Manual

Page 72

Advertising
background image

72

11 Supplement

VEGABAR 83 • Profibus PA

45037-EN-131107

Housing material

Version

IP-protection class

NEMA protection

Stainless steel, investment

casting

Single chamber

IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)

NEMA 4X/6P
NEMA 4X

Double chamber

IP 66/IP 67
IP 66/IP 68 (0.2 bar)

NEMA 4X
NEMA 4X

Stainless steel

Transmitter for external

housing

IP 68 (25 bar)

-

Overvoltage category

III

Protection class

II

Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments must be carefully noted.

They are part of the delivery or can be downloaded under www.vega.com and "VEGA Tools" as

well as under "Downloads" and "Approvals".

11.2 Communication Profibus PA

Instrument master file

The instrument master file (GSD) contains the characteristic data of the Profibus PA instrument.

These data are, e.g. the permissible transmission rates as well as information on diagnostics values

and the format of the measured value outputted by the PA instrument.
A bitmap file is also provided for the Profibus network planning tool. This file is installed automati-

cally when the GSD file is integrated. The bitmap file is used for symbolic indication of the PA instru-

ment in the configuration tool.

ID number

Each Profibus instrument gets an unambiguous ident number (ID number) from the Profibus user

organisation (PNO). This ID number is also included in the name of the GSD file. Optionally to this

manufacturer-specific GSD file, PNO provides also a general so-called profile-specific GSD file. If

the general GSD file is used, the sensor must be set to the profile-specific ident number via the DTM

software. By default, the sensor operates with the manufacturer-specific ID number. When using the

instruments on a segment coupler SK-2 or SK-3, no special GSD files are required.

Module of the PA sensors

For the cyclic data traffic, VEGABAR 83 provides the following modules:

AI FB1 (OUT)

– Out value of the AI FB1 after scaling

AI FB2 (OUT)

– Out value of the AI FB2 after scaling

AI FB3 (OUT)

– Out value of the AI FB3 after scaling

Free Place

– This module must be used if a value in the data telegram of the cyclical data traffic should not

be used (e.g. replacement of temperature and Additional Cyclic Value)

A maximum of three modules can be active. By means of the configuration software of the Profibus

Advertising