Table 5. mon_ and en_out_ assignment registers – Rainbow Electronics MAX16066 User Manual

Page 15

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

______________________________________________________________________________________ 15

Figure

3. Delay and Reset Timing

Table

5. MON_ and EN_OUT_ Assignment Registers

REGISTER

ADDRESS

FLASH

ADDRESS

BIT RANGE

DESCRIPTION

7Eh

27Eh

[3:0]

MON1

[7:4]

MON2

7Fh

27Fh

[3:0]

MON3

[7:4]

MON4

80h

280h

[3:0]

MON5

[7:4]

MON6

81h

281h

[3:0]

MON7

[7:4]

MON8

82h

282h

[3:0]

MON9

[7:4]

MON10

83h

283h

[3:0]

MON11

[7:4]

MON12

SLOT 0

EN_OUT1

BOTH ARE

ASSIGNED
TO SLOT 1

MON4

EN_OUT2

MON3

MON5

RESET

EN

SLOT 1

t

FAULT

OV

UV

SLOT1-SLOT2

DELAY

SLOT1-SLOT2

DELAY

MON4 MUST

REACH UV

THRESHOLD BY THIS

TIME

UV/OV

MONITORING BEGINS

WHEN MON4
REACHES UV

THRESHOLD

SLOT 2

FINAL SLOT

(PRIMARY

SEQUENCE)

RESET

TIMEOUT

BOTH ARE

ASSIGNED
TO SLOT 2

Advertising