Table 23. reset output configuration – Rainbow Electronics MAX16066 User Manual

Page 36

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

36 _____________________________________________________________________________________

Table

23. Reset Output Configuration

REGISTER

ADDRESS

FLASH

ADDRESS

BIT RANGE

DESCRIPTION

3Bh

23Bh

[1:0]

Reset Output Depends On:
00 = Undervoltage threshold violations
01 = Early warning threshold violations
10 = Overvoltage threshold violations
11 = Undervoltage or overvoltage threshold violations

[2]

0 = Active-low
1 = Active-high

[3]

0 = Push-pull
1 = Open drain

[7:4]

Reset Timeout Period:
0000 = 25Fs
0001 = 1.5ms
0010 = 2.5ms
0011 = 4ms
0100 = 6ms
0101 = 10ms
0110 = 15ms
0111 = 25ms
1000 = 40ms
1001 = 60ms
1010 = 100ms
1011 = 150ms
1100 = 250ms
1101 = 400ms
1110 = 600ms
1111 = 1s

3Ch

23Ch

[0]

Reset Soft Trigger:
0 = Normal RESET behavior
1 = Force RESET to assert

[1]

1 = RESET depends on MON1

[2]

1 = RESET depends on MON2

[3]

1 = RESET depends on MON3

[4]

1 = RESET depends on MON4

[5]

1 = RESET depends on MON5

[6]

1 = RESET depends on MON6

[7]

1 = RESET depends on MON7

3Dh

23Dh

[0]

1 = RESET depends on MON8

[1]

1 = RESET depends on MON9

[2]

1 = RESET depends on MON10

[3]

1 = RESET depends on MON11

[4]

1 = RESET depends on MON12

[7:5]

Reserved