Electrical characteristics – Rainbow Electronics MAX16066 User Manual

Page 5

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

_______________________________________________________________________________________ 5

ELECTRICAL CHARACTERISTICS

(V

CC

= 2.8V to 14V, T

A

= -40NC to +85NC, unless otherwise specified. Typical values are at ABP = DBP = V

CC

= 3.3V, T

A

= +25NC.)

(Note 1)

Note 1: Specifications are guaranteed for the stated global conditions, unless otherwise noted. 100% production tested at T

A

=

+25NC and T

A

= +85NC. Specifications at T

A

= -40NC are guaranteed by design.

Note 2: For V

CC

of 3.6V or lower, connect V

CC

, DBP, and ABP together. For higher supply applications, connect only V

CC

to the

supply rail.

Note 3: Applies to RESET, fault, autoretry, sequence delays, and watchdog timeout.
Note 4: Total unadjusted error is a combination of gain, offset, and quantization error.

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Output Fall Time

t

OF

C

BUS

= 10pF to 400pF

250

ns

Data Hold Time

t

HD:DAT

From 50% SCL falling to SDA change

0.3

0.9

μs

Pulse Width of Spike Suppressed

t

SP

30

ns

JTAG INTERFACE
TDI, TMS, TCK Logic-Low Input
Voltage

V

IL

Input voltage falling

0.8

V

TDI, TMS, TCK Logic-High Input
Voltage

V

IH

Input voltage rising

2

V

TDO Logic-Output Low Voltage

V

OL

I

SINK

= 3mA

0.4

V

TDO Logic-Output High Voltage

V

OH

I

SOURCE

= 200μA

2.4

V

TDI, TMS Pullup Resistors

R

PU

Pullup to DBP

40

50

60

I/O Capacitance

C

I/O

5

pF

TCK Clock Period

t

1

1000

ns

TCK High/Low Time

t

2

, t

3

50

500

ns

TCK to TMS, TDI Setup Time

t

4

15

ns

TCK to TMS, TDI Hold Time

t

5

10

ns

TCK to TDO Delay

t

6

500

ns

TCK to TDO High-Z Delay

t

7

500

ns

Advertising