Rainbow Electronics MAX16066 User Manual

Page 31

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

______________________________________________________________________________________ 31

Table

19. Nonvolatile Fault Log Registers (continued)

Table

20. Autoretry Configuration

FLASH ADDRESS

BIT RANGE

DESCRIPTION

202h

[0]

Fault log triggered on MON9

[1]

Fault log triggered on MON10

[2]

Fault log triggered on MON11

[3]

Fault log triggered on MON12

[4]

Fault log triggered on overcurrent

[5]

Fault log triggered on EXTFAULT

[7:6]

Not used

203h

[7:0]

MON1 ADC output bits 9–2

204h

[7:0]

MON2 ADC output bits 9–2

205h

[7:0]

MON3 ADC output bits 9–2

206h

[7:0]

MON4 ADC output bits 9–2

207h

[7:0]

MON5 ADC output bits 9–2

208h

[7:0]

MON6 ADC output bits 9–2

209h

[7:0]

MON7 ADC output bits 9–2

20Ah

[7:0]

MON8 ADC output bits 9–2

20Bh

[7:0]

MON9 ADC output bits 9–2

20Ch

[7:0]

MON10 ADC output bits 9–2

20Dh

[7:0]

MON11 ADC output bits 9–2

20Eh

[7:0]

MON12 ADC output bits 9–2

20Fh

[7:0]

Current-sense ADC output bits 9–2

REGISTER

ADDRESS

FLASH

ADDRESS

BIT RANGE

DESCRIPTION

74h

274h

[2:0]

Retry Delay:
000 = 20ms
001 = 40ms
010 = 80ms
011 = 150ms
100 = 280ms
101 = 540ms
110 = 1s
111 = 2s

[4:3]

Autoretry/Latch Mode:
00 = Latch
01 = Retry 1 time
10 = Retry 3 times
11 = Always retry