Rainbow Electronics MAX16066 User Manual

Page 30

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

30 _____________________________________________________________________________________

Table

18. Critical Fault Configuration (continued)

Table

19. Nonvolatile Fault Log Registers

REGISTER

ADDRESS

FLASH

ADDRESS

BIT

RANGE

DESCRIPTION

70h

270h

[0]

1 = Fault log triggered when MON5 is above its overvoltage threshold

[1]

1 = Fault log triggered when MON6 is above its overvoltage threshold

[2]

1 = Fault log triggered when MON7 is above its overvoltage threshold

[3]

1 = Fault log triggered when MON8 is above its overvoltage threshold

[4]

1 = Fault log triggered when MON9 is above its overvoltage threshold

[5]

1 = Fault log triggered when MON10 is above its overvoltage threshold

[6]

1 = Fault log triggered when MON11 is above its overvoltage threshold

[7]

1 = Fault log triggered when MON12 is above its overvoltage threshold

71h

271h

[0]

1 = Fault log triggered when MON1 is above/below the early threshold warning

[1]

1 = Fault log triggered when MON2 is above/below the early threshold warning

[2]

1 = Fault log triggered when MON3 is above/below the early threshold warning

[3]

1 = Fault log triggered when MON4 is above/below the early threshold warning

[4]

1 = Fault log triggered when MON5 is above/below the early threshold warning

[5]

1 = Fault log triggered when MON6 is above/below the early threshold warning

[6]

1 = Fault log triggered when MON7 is above/below the early threshold warning

[7]

1 = Fault log triggered when MON8 is above/below the early threshold warning

72h

272h

[0]

1 = Fault log triggered when MON9 is above/below the early threshold warning

[1]

1 = Fault log triggered when MON10 is above/below the early threshold warning

[2]

1 = Fault log triggered when MON11 is above/below the early threshold warning

[3]

1 = Fault log triggered when MON12 is above/below the early threshold warning

[4]

1 = Fault log triggered when overcurrent early threshold is exceeded

[5]

1 = EXTFAULT pulled low externally causes sequencer to enter fault state, turning off
all EN_OUT_s
0 = EXTFAULT pulled low externally does not cause sequencer to enter fault state

[7:6]

Reserved

FLASH ADDRESS

BIT RANGE

DESCRIPTION

200h

[4:0]

Sequencer state where the fault has happened (see Table 1 for state codes)

[7:5]

Not used

201h

[0]

Fault log triggered on MON1

[1]

Fault log triggered on MON2

[2]

Fault log triggered on MON3

[3]

Fault log triggered on MON4

[4]

Fault log triggered on MON5

[5]

Fault log triggered on MON6

[6]

Fault log triggered on MON7

[7]

Fault log triggered on MON8