Table 24. watchdog configuration – Rainbow Electronics MAX16066 User Manual

Page 38

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

38 _____________________________________________________________________________________

Figure

10. Watchdog Startup Sequence with Watchdog Reset Enable Bit Set to ‘1’

Table

24. Watchdog Configuration

WDI

WDO

0V

0V

V

CC

V

CC

0V

V

CC

< t

WDI

1µs

RESET

< t

WDI

t

WDI

t

RP

< t

WDI_STARTUP

REGISTER

ADDRESS

FLASH

ADDRESS

BIT RANGE

DESCRIPTION

73h

273h

[4]

1 = Independent mode
0 = Dependent mode

76h

276h

[7]

1 = Watchdog affects RESET output
0 = Watchdog does not affect RESET output

[6:4]

Watchdog Startup Delay:
000 = No initial timeout
001 = 30s
010 = 40s
011 = 80s
100 = 120s
101 = 160s
110 = 220s
111 = 300s

[3:0]

Watchdog Timeout:
0000 = Watchdog disabled
0001 = 1ms
0010 = 2ms
0011 = 4ms
0100 = 8ms
0101 = 14ms
0110 = 27ms
0111 = 50ms
1000 = 100ms
1001 = 200ms
1010 = 400ms
1011 = 750ms
1100 = 1.4s
1101 = 2.7s
1110 = 5s
1111 = 10s

Advertising