Rainbow Electronics MAX16066 User Manual

Page 16

Advertising
background image

12-Channel/8-Channel, Flash-Configurable System

Managers with Nonvolatile Fault Registers

MAX16065/MAX16066

16 _____________________________________________________________________________________

Table

5. MON_ and EN_OUT_ Assignment Registers (continued)

Table

6. MON_ and EN_OUT_ Slot Assignment Codes

REGISTER

ADDRESS

FLASH

ADDRESS

BIT RANGE

DESCRIPTION

84h

284h

[3:0]

EN_OUT1

[7:4]

EN_OUT2

85h

285h

[3:0]

EN_OUT3

[7:4]

EN_OUT4

86h

286h

[3:0]

EN_OUT5

[7:4]

EN_OUT6

87h

287h

[3:0]

EN_OUT7

[7:4]

EN_OUT8

88h

288h

[3:0]

EN_OUT9

[7:4]

EN_OUT10

89h

289h

[3:0]

EN_OUT11

[7:4]

EN_OUT12

SLOT ASSIGNMENT

CODE

MON_ DESCRIPTION

OUT_ DESCRIPTION

0000

Not assigned

Not assigned

0001

Slot 1

Slot 1

0010

Slot 2

Slot 2

0011

Slot 3

Slot 3

0100

Slot 4

Slot 4

0101

Slot 5

Slot 5

0110

Slot 6

Slot 6

0111

Slot 7

Slot 7

1000

Slot 8

Slot 8

1001

Slot 9

Slot 9

1010

Slot 10

Slot 10

1011

Slot 11

Slot 11

1100

Slot 12

Slot 12

1101

Monitoring only, primary sequence

General-purpose input (EN_OUT9–EN_OUT12 only)

1110

Monitoring only, secondary sequence

General-purpose output (EN_OUT9–EN_OUT12 only)

1111

Not assigned

Not assigned

Advertising